Int J Clin Pediatr
International Journal of Clinical Pediatrics, ISSN 1927-1255 print, 1927-1263 online, Open Access
Article copyright, the authors; Journal compilation copyright, Int J Clin Pediatr and Elmer Press Inc
Journal website http://www.theijcp.org

Original Article

Volume 9, Number 3, September 2020, pages 72-76


Impact of Oxygen Delivery Patterns on Arterial Oxygen Saturation Among Children

Deepali Gunjala, d, Radha Vaidyanathanb, Vaibhav Bhosalec

aSeva Nursing College, Shrirampur, Ahmednagar, Maharashtra, India
bChild Health, Research and Hospital Management, Trichy, Tamilnadu, India
cPravara Institute of Medical Sciences, College of Nursing, Loni Bk, Ahmednagar, Maharashtra, India
dCorresponding Author: Deepali Gunjal, Seva Nursing College, Shrirampur, Ahmednagar, Maharashtra, 413 736, India

Manuscript submitted June 22, 2020, accepted July 10, 2020, published online July 30, 2020
Short title: Impact of Oxygen Delivery Patterns
doi: https://doi.org/10.14740/ijcp388

Abstract▴Top 

Background: Adequate oxygenation to treat hypoxia by suitable oxygen delivery pattern is the essence of pediatric critical care medicine. Monitoring oxygen saturation (SpO2) is thus essential in order to decide course of treatment. It is commonly carried out using painless sequential non-invasive pulse oximetry as well by severely painful random arterial blood gas (ABG) analysis.

Methods: This study compared both methods to determine the impact of various oxygen delivery patterns upon SpO2 at bedside for meaningful and continuous evaluation. In a prospective cohort adopted for study, 60 children from acute pediatric wards of an academic tertiary referral hospital were observed. Children were eligible for enrollment using cross sectional approach, if the treating pediatricians ordered an ABG, on pulse oximetry monitoring with oxygen support by any oxygen delivery device using a validated checklist.

Results: Among all the samples, 60 % were infants and 55 % were male. Complaints on admission were vomiting (35%), shortness of breath (33%), diarrhea (28%), lethargy (31%) and Kussmaul breathing (30%). SpO2 was > 90% for 88% of children. Oxy hood box was used to deliver oxygen to 73% of children. SpO2 had positive correlation with oxygen delivery methods (r = 0.8) and partial pressure of oxygen (PaO2) by ABG analysis had positive correlation with SpO2 by pulse oximetry (r = 0.9).

Conclusions: Pulse oximetry can be used as a reliable bed side tool to evaluate oxygen delivery patterns and diagnose early respiratory failure in emergency settings where ABG analysis facility is not available.

Keywords: ABG analysis; Arterial oxygen saturation; Oxygen delivery patterns

Introduction▴Top 

Oxygen therapy plays a major role for respiratory care to treat hypoxemia in pediatric critical care medicine. Oxygen delivery patterns have devices that vary from a simple nasal cannula to sophisticated humidified systems. Several methods of non-invasive oxygen delivery patterns for children include head box oxygen (oxy hood), free flow oxygen source held close to infants’ nose, facemask, nasal prongs, nasal catheter and nasopharyngeal catheter [1]. Undoubtedly, oxygen therapy is an important tool that has saved many lives and improved others [2]. Monitoring oxygen saturation (SpO2) is thus essential in order to decide course of treatment. It is commonly carried out using painless sequential non-invasive pulse oximetry as well by severely painful random arterial blood gas (ABG) analysis. Pulse oximetry is a monitoring method that indirectly determines oxygenation adequacy in a non-invasive manner [3]. ABG analysis checks how well lungs are able to move oxygen into blood and remove carbon dioxide from blood which is an invasive method [4]. ABG analysis is helpful to assess effectiveness of ventilation, circulation and perfusion especially in critically ill children.

Among 334 million people who suffer from asthma globally, 14% are children with chronic diseases of childhood including respiratory disorders. In India among 26.3 million cases, the incidence rate of respiratory disorders in children is about 2,173 cases per lakh who at some point of treatment require oxygen or ventilation. In order to assess oxygenation correctly, an understanding of the ABG values, relationship between partial pressure of oxygen (PaO2) and SpO2 are required [5].

ABG analysis provide a snapshot of acid base balance by measuring hydrogen ion concentration in blood (pH), oxygen saturation (SaO2), PaO2, partial pressure of carbon dioxide (PaCO2), concentration of bicarbonate (HCO3-) and base excess in arterial blood. In addition, it indicates the primary source of disturbance (i.e., respiratory or metabolic) in homeostasis and how effectively patient’s body is compensating for the acid base disturbance and whether the patient’s total blood volume is adequate for transporting all nutrients that the body’s tissues require [6].

However, ABG is a painful and expensive test. One ABG typically leads to a cascade of ABGs, multiplying costs and blood loss. ABGs may be contaminated with venous blood as it requires expert skill to perform in children with very thin blood vessels. Also obtaining an arterial blood sample in children consumes lot of time owing to various factors and that may delay suitable management such as pediatric intensive care unit (PICU) transfer or intubation. ABG only measures oxygenation at a single time point and dynamic changes in PaO2 may widely get misinterpreted.

On the other hand, pulse oximetry is a quick way of measuring SpO2 of peripheral arterial hemoglobin as it is readily available but cannot detect hypercapnia or acidosis. It relies on the fact that oxygenated and deoxygenated hemoglobin absorb different wavelengths of light. Although ABG analysis remains the gold standard, pulse oximetry assessment has been shown to correlate with ABG analysis results and proposed as a safer less invasive, less painful alternative in children. Aim of this study was to gather evidence by comparison and evaluate SpO2 after administering oxygen through various oxygen delivery patterns with simultaneous pulse oximetry and ABG analysis to find correlation among them, if any.

Materials and Methods▴Top 

In a prospective cross-sectional cohort design adopted for study 60 children from birth to 6 years of age admitted in acute pediatric wards of a single academic tertiary referral hospital in rural setting over a period of 4 months were studied using a validated checklist. Children were eligible for enrollment, if the child is simultaneously put on pulse oximetry monitoring with oxygen support by any oxygen delivery device and the treating pediatricians ordered at least two ABG tests on consecutive days. These children were followed up till they were independent of oxygen supply or for 5 days after admission. Children who were alive at the exit of study only were included for final data in order to have a homogenous group. Children with congenital anomalies or known impaired peripheral perfusion disorders were excluded. This study has been approved by the institutional research/ethical committee.

Pulse oximeter used was 2060 model (EMCO Meditek Pvt. Ltd, Mumbai, India) calibrated for accuracy of reading. Structured observational checklist was prepared that collected brief identification profile, clinical features and investigative profile of child including results of ABG analysis that used the Respiratory Opposite Metabolic Equal (ROME) method for evaluation. After obtaining pH value, respiratory and metabolic components were studied. If the pH was abnormal, it was determined whether the respiratory value (PaCO2) and metabolic value (HCO3-) are consistent with pH value to determine whether any compensation is present using the following interpretation table prepared (Table 1) [5]. Interpretation was limited to clinical pictures connected to oxygenation status and its related components and did not divulge into its etiological trajectories.

Table 1.
Click to view
Table 1. Interpretation Guidelines for ABG Analysis Results
 
Results▴Top 

Basic demography profile of samples

Children in majority were infants (62%), of second birth order (53%), male in gender (55%), from rural area (53%) and had nuclear type of family predominance (63%). Among them 57% had two children in family, 52% of fathers and 50% of mothers were graduates, majority of whom (57% fathers, 38% mothers) were employed in private firms followed by agriculture as an occupation (17% fathers and 37% mothers). Parents were between 25 to 30 years old (62% fathers and 65% mothers).

Oxygen delivery patterns and SpO2 levels using pulse oximetry

On admission 73% of children received oxygen by oxy hood at the rate of 6 to 10 L per min that sustained SpO2 > 90% (Table 2). They required oxygen supply for 4 days when 97% of samples’ SpO2 was > 90% using pulse oximetry. Those who received oxygen by nasal prongs on admission were 11% but had to be shifted to face mask on day 2 owing to discomfort, restlessness and difficulty in keeping the prongs in situ position. Both face mask and oxy hood at standard rates given were continued up to maximum of 4 days since admission when children improved (60%) and were not dependent on oxygen delivery on day 5.

Table 2.
Click to view
Table 2. Description of Oxygen Delivery Patterns with SpO2 and PaO2 Levels
 

It was also observed that 88% children who had > 90% SpO2 on the day of admission had decreased SpO2 on day 2 after which they improved on day 5 without oxygen. Both oxy hood box and face mask were equally effective at the rates standardized for oxygen delivery to sustain > 90% SpO2. However, oxy hood was used among 75% of children on oxygen on day 4 than face mask. It may be attributed to the samples being infants in majority that endorses preference for oxy hood box pattern of oxygen delivery for younger children.

Oxygen delivery patterns and PaO2 using ABG analysis

On admission 82% had PaO2 in the normal acceptable range which is slightly lower than the SpO2 findings by pulse oximeter (Table 2). Other 18% had PaO2 of < 80 mm Hg that increased to 28% on day 2 which improved to 15-17% on day 3 and 4 respectively. This trend is comparable with inputs from SpO2 observations used simultaneously.

ABG analysis report of samples

ABG analysis report interpretation (Fig. 1) found that 35% had respiratory acidosis, 8% had respiratory alkalosis, 42% had metabolic acidosis, 13% had metabolic alkalosis and 2% were normal on admission. Consecutive analysis report findings noted in Table 2 with specific focus to SpO2 and PaO2 substantiates hypothesis that support correlation between both the levels. It is further observed that O2 saturation varied with PaO2 in a nonlinear relationship as PaCO2 was not affected initially on admission but the disturbance was evident on day 2 supporting the notion that the diffusion capacity of CO2 is much higher than that of oxygen and only when alveolar level ventilation is impaired its values get affected. The number of ABGs ordered per sample was limited to a maximum of two in 32%, three in 68% and four in 20% of children, who were critically ill and thus a cascade of reports were also restricted as days advanced.

Figure 1.
Click for large image
Figure 1. ABG analysis report interpretation of children. ABG: arterial blood gas.

As shown in Table 3 on admission majority of children with respiratory acidosis manifested with altered sensorium (44%), respiratory alkalosis with restlessness (84%) and hyperventilation, metabolic acidosis with decreased cardiac function (79%) and Kussmaul breathing, metabolic alkalosis with refusal to feeds (50%) and irritability (64%) and all four disturbances had children presenting with unspecific features in varying proportions mentioned. Treatment regimen offered to children under SpO2 and PaO2 monitoring were oxygen administration (100%), ventilation with bilevel positive airway pressure (BiPAP) and continuous positive airway pressure (CPAP) (62%), antibiotics (100%), K+ supplements (27%), sodium bicarbonate (NaHCO3) supplements (32%) and correction of primary problems using medications, intravenous (IV) fluids plus supportive nursing care (100%).

Table 3.
Click to view
Table 3. Comparative Clinical Profile of Children on Admission Under SpO2 and PaO2 Monitoring Based on ABG Interpretation
 

Correlation coefficient test was used to evaluate correlation between SpO2 and oxygen delivery patterns that obtained r value of 0.8, which interprets that SpO2 had positive correlation with oxygen delivery methods. Same test used to evaluate correlation between PaO2 and SpO2 obtained r value of 0.9 that it interprets positive correlation between PaO2 had with SpO2.

Discussion▴Top 

Supplemental oxygen in pediatrics poses challenges owing to wide range of size in choosing an appropriate oxygen delivery pattern to meet dynamic physiological instability. ABG analysis and pulse oximetry are two types of measurements that provide insight into oxygenation levels in child receiving continuous ventilation support. Pulse oximeter is an important monitoring tool that allows decisions on constant titration of oxygen supply dose, early diagnosis of desaturation upon which several studies have debated its benefits and disadvantages for over two decades and more. However, the confidence quotient on its extensive use at critical/peripheral pediatric care practice is with hesitancy resulting its use as an adjunct monitoring device and instead, trends of sequential ABG tests remain as the mainstay in treatment decisions. This study compared commonly used oxygen delivery patterns and evaluated its impact on monitoring simultaneously with both methods of SpO2 with its correlation.

Infants age group received oxygen supply more commonly among children which is noted by Ramachandran et al [7] (75%), Kumar et al [6] (68%), similar to the finding in this study (62%). It could be because that they are the commonest pediatric age group who are affected by respiratory disorders. Male predominance of 55% among samples is also observed by other studies - Tiwari et al [8] (52%), LeCleir et al [9] (57%) and Ramachandran et al [7] (73%), all of which have not shown any statistical significance.

Requirement of oxygen supply for an average period of 4 days (96 h) is shared by LeCleir et al [9] and Bhargava et al [10]. This clinical variable is significant as it decides the length of their stay (LOS) and course in hospital. It is possible that due to a true presentation with illness severity which children reach tertiary care centers mandates lengthy O2 delivery. Oxy hood and face mask as an effective and well tolerated method for oxygen administration in children has been concluded by Kumar et al [6] (70%) using a tolerance score, in synchrony as this study (73% on admission to 50% subsequently).

There was no significant difference among two high-flow methods (face mask and head box) to maintain oxygenation and saturation. Yet the difference between high-flow and low-flow methods (nasal prongs in this study and nasal catheter in other studies) in their ability to relieve hypoxemia was highly significant (P = 0.001 and P = 0.030, respectively). This may be attributed to the pain and discomfort caused to the fragile skin with constant pressure exerted on nose, cheeks and tapes used on face as a precaution to secure them. However, Walsh et al [2] opines otherwise in their review on these devices in view of the cost involved during hospitalization.

Pulse oximetry has been evaluated in several studies [6, 7, 10-14] as a reliable tool that has shown positive results in measuring SpO2 with equal accuracy in most scenarios in comparison to ABG analysis. A correlation between SpO2 and PaO2 was proposed [11] with a simple hypothesis that if the monitor is showing a SpO2 of 70%, we can almost consider a value of PaO2 to be around 35 mm Hg. Use of noninvasive indices (SpO2) was suggested [10] in place of invasive indices (PaO2) as surrogate markers of oxygenation in critically ill children. Another study [7] observed that pulse oximeter detected SpO2 comparable to arterial SpO2 in all the patients with cyanotic heart diseases, even though most of them did not present with clinically significant cyanosis. This study concurred with above findings as well with other studies [12, 13] which found that PaO2 had positive correlation with SpO2 and noted that readings of SpO2 of > 90% correlated with PaO2 of > 80 mm Hg for > 94% of the time with statistically significant coefficient values of r = 0.8 with oxygen delivery patterns and r = 0.9 with simultaneous SpO2 and PaO2 recordings.

Moreover, it was observed clinically that a pulse oximeter provided measurements of heart rate as an additional vital sign aided initiation of appropriate care measures for child. A study [15] on the contrary cautioned against surrogate use of SpO2 for PaO2. Reason could be illustrated with the principle of differential absorption of light by oxygenated and deoxygenated blood where increased carboxyhemoglobin levels are independently associated with the percentage difference between SpO2 and PaO2 and hence pulse oximetry does not provide insight on the level of PaCO2 or pH. However, simultaneous pulse oximetry measurements accurately projected oxygenation status in children undergoing various oxygen delivery patterns with significant statistical correlation of arterial saturation measured by ABG analysis in this study. The rapid response time of SpO2 offered prompt and important decisions at bedside guiding treatment regarding oxygen therapy.

ABG analysis reports highlighted comparable acid base disturbances with 42% samples having metabolic acidosis similar to study samples by Anitha et al [16] (47%), which commonly occurs in critically ill children [17]. BiPAP and CPAP had been found as the best ventilation mode for 78% participants to treat respiratory disorders in consistency with prescription by Abramo et al [18]. NaHCO3 supplementation remained as the mainstay in treating acid base disorders, a common clinical practice noted by Daly et al [19].

Conclusions

Oxygen delivery patterns by oxy hood and face mask have better tolerance and comfort among infants with an effective impact to maintain SpO2. There is a positive correlation between oxygen delivery methods with PaO2 and SpO2. Pulse oximetry can be used as a reliable bed side tool to evaluate effectiveness of oxygen delivery patterns and diagnose early respiratory failure superior to ABG in emergency, peripheral and rural healthcare settings where ABG analysis facility is not available and cost is a considerable factor.

Acknowledgments

The authors would like to thank Prarvara Institute of Medical Sciences (Deemed to be University) and Pravara Rural Hospital Loni authorities for all.

Financial Disclosure

None to declare.

Conflict of Interest

None to declare.

Informed Consent

The informed consents have been obtained from the parents.

Author Contributions

DG: Literature exploration, research data collection, statistical analysis and first draft. LVR: Guide, concept, research design, literature exploration and final draft. VB: Research guidance, clinical support, co-ordination.

Data Availability

The data supporting the findings of this study are available from the corresponding author upon reasonable request.


References▴Top 
  1. Frey B, Shann F. Oxygen administration in infants. Arch Dis Child Fetal Neonatal Ed. 2003;88(2):F84-88.
    doi pubmed
  2. Walsh BK, Smallwood CD. Pediatric oxygen therapy: a review and update. Respir Care. 2017;62(6):645-661.
    doi pubmed
  3. Soini UM, Clarke S, Solberg MT. Oxygen treatment of critically ill children: A lack of evidence. Nordic Journal of Nursing Research. 2016;37(3):127-134.
    doi
  4. Hasan A. The non-invasive monitoring of blood oxygen and Carbon dioxide levels. Handbook of blood gas/acid base Interpretation. 2013:51-93.
    doi
  5. Larkin BG, Zimmanck RJ. Interpreting arterial blood gases successfully. AORN J. 2015;102(4):343-354; quiz 355-347.
    doi pubmed
  6. Kumar RM, Kabra SK, Singh M. Efficacy and acceptability of different modes of oxygen administration in children: implications for a community hospital. J Trop Pediatr. 1997;43(1):47-49.
    doi pubmed
  7. Ramachandran S, Gera A, Gera R, Kataria S, Roy MP. Accuracy of pulse oximetry versus arterial blood gas in screening cyanotic heart. International Journal of Contemporary Pediatrics. 2016;3(3):983-987.
    doi
  8. Tiwari S, Soumya T, Nangia S, Saili A. Oxygen saturation profile in healthy term neonates in the immediate post-natal period. Int J Clin Pediatr. 2013;2(1):19-23.
    doi
  9. LeCleir B, Jurecko L, Davis AT, et al. Implementing an oxygen supplementation and monitoring protocol on inpatient pediatric Bronchiolitis: An exercise in de-implementation. Int J Pediatr. 2017;3169098:1-7.
    doi pubmed
  10. Bhargava S, Pooni P, Singla S. Comparison of SpO2 and PaO2 based indices of oxygenation in children with respiratory failure. Pediatric Critical Care Medicine. 2018;19(6S):120.
    doi
  11. Madan A. Correlation between the levels of SpO2 and PaO2. Lung India. 2017;34(3):307-308.
  12. Ramy R, El-Sberbihy, Ahmed A, El-Ezz A, Ibrahim, Yasser M, El-raouf A, et al. Pulse oximetry in comparison to arterial blood oxygen saturation in children with bronchial asthma coming to the emergency room. Tanta Medical Journal. 2018;46(2):93-98.
    doi
  13. Ross EM, Matteucci MJ, Shepherd M, Barker M, Orr L. Measuring arterial oxygenation in a high altitude field environment: comparing portable pulse oximetry with blood gas analysis. Wilderness Environ Med. 2013;24(2):112-117.
    doi pubmed
  14. Fanconi S, Doherty P, Edmonds JF, Barker GA, Bohn DJ. Pulse oximetry in pediatric intensive care: comparison with measured saturations and transcutaneous oxygen tension. J Pediatr. 1985;107(3):362-366.
    doi
  15. Bhattacharyya A, Ramos J, Tonelli AR. Discrepancy between pulse oximetry and arterial oxygen saturation at rest and during exercise. American Journal of Respiratory and Critical Care Medicine. 2020;201:A5451. Available at: https://www.atsjournals.org/doi/abs/10.1164/ajrccm-conference.2017.195.1.
  16. Anitha B, Siromani SSM. Acid base disturbances in sick neonates - An observational study in a tertiary care centre. IOSR Journal of Dental and Medical Sciences. 2015;14(12):35-38.
  17. Sekaran DV, Subramanyam L, Balachandran A. Arterial blood gas analysis in clinical practice. Indian Pediatr. 2001;38(10):1116-1128.
  18. Abramo T, Williams A, Mushtaq S, Meredith M, Sepaule R, Crossman K, Burney Jones C, et al. Paediatric ED BiPAP continuous quality improvement programme with patient analysis: 2005-2013. BMJ Open. 2017;7(1):e011845.
    doi pubmed
  19. Daly K, Farrington E. Hypokalemia and hyperkalemia in infants and children: pathophysiology and treatment. J Pediatr Health Care. 2013;27(6):486-496; quiz 497-488.
    doi pubmed


This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.


International Journal of Clinical Pediatrics is published by Elmer Press Inc.

 

Browse  Journals  

     

Journal of Clinical Medicine Research

Journal of Endocrinology and Metabolism

Journal of Clinical Gynecology and Obstetrics

World Journal of Oncology

Gastroenterology Research

Journal of Hematology

Journal of Medical Cases

Journal of Current Surgery

Clinical Infection and Immunity

Cardiology Research

World Journal of Nephrology and Urology

Cellular and Molecular Medicine Research

Journal of Neurology Research

International Journal of Clinical Pediatrics

 

 

 

 

 

International Journal of Clinical Pediatrics, quarterly, ISSN 1927-1255 (print), 1927-1263 (online), published by Elmer Press Inc.                     
The content of this site is intended for health care professionals.
This is an open-access journal distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted
non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Creative Commons Attribution license (Attribution-NonCommercial 4.0 International
CC-BY-NC 4.0)


This journal follows the International Committee of Medical Journal Editors (ICMJE) recommendations for manuscripts submitted to biomedical journals,
the Committee on Publication Ethics (
COPE) guidelines, and the Principles of Transparency and Best Practice in Scholarly Publishing.

website: www.theijcp.org   editorial contact: editor@theijcp.org
Address: 9225 Leslie Street, Suite 201, Richmond Hill, Ontario, L4B 3H6, Canada

© Elmer Press Inc. All Rights Reserved.



Disclaimer: The views and opinions expressed in the published articles are those of the authors and do not necessarily reflect the views or opinions of the editors and Elmer Press Inc. This website is provided for medical research and informational purposes only and does not constitute any medical advice or professional services. The information provided in this journal should not be used for diagnosis and treatment, those seeking medical advice should always consult with a licensed physician.